Skip to main content
phone 516-883-1700
2 Manhasset Ave. Port Washington, NY 11050
Toggle menumenu toggle
Industrial Test Equipment Co., Inc.
  • Compare

  • Power Supplies expand drowpdown list close drowpdown list Power Supplies
    • AC Voltage Sources 80-500 watts
    • AC Voltage Sources 1000-3000 watts
    • RF Power Amplifiers 50-1000 watts
    • AC Current Sources 250-500 watts
    • AC Current Sources 1000-3000 watts
    • Frequency Converters 80-3000 watts
    • AC Power Amplifiers (Voltage Mode)
    • AC Power Amplifiers (Current Mode)
    • Plasma Power Supplies
    • Dedicated AC Power Sources
    • IEEE Controlled Oscillators
    • Plug-in Oscillators
    • Three Phase Linear
  • Labels & Markers expand drowpdown list close drowpdown list Labels & Markers
    • Cable Markers
    • Engraved Nameplates and Tags
    • Hot Stamped Markers
  • Gas Detectors expand drowpdown list close drowpdown list Gas Detectors
    • Carbon Monoxide
    • Methane
    • Multi-Gas
    • Telecom
    • Propane
    • Hydrogen
  • Sign in or Register
  1. Home
  2. Gas Detectors
  3. Propane Direct Hook Up
Propane Direct Hook Up
  • Propane Direct Hook Up

Propane Direct Hook Up

Model HIC-813 or HIC-822 (General Purpose)

Propane Direct Hook Up

MSRP:
Was:
Now: $320.00
(You save )
(No reviews yet) Write a Review

Write a Review

Propane Direct Hook Up
Propane Direct Hook Up

SKU:
HIC-813
UPC:
pdf:
HIC-813datasheet.pdf
model:
HIC-813
pdf_2:
HIC-822datasheet.pdf
model_2:
HIC-822
  • Facebook
  • Email
  • Print
  • Twitter
  • Pinterest
Propane Direct Hook Up
  • Propane Direct Hook Up

FEATURES

  • 1-year limited warranty
  • Three methods of communicating alarm: 85dB internal buzzer, red LED and 10A, 250V dry relay
  • Equipped with a UL approved 120V AC to 12V DC, 500mA adaptor. 230V AC to 12V DC adaptor can be substituted if specified.
  • Programmable delay to activate the alarm relay. Delay are 0, 4 or 8 minutes. This reduces nuisance alarms caused by short whiffs of gas.
  • The recommended area for one detector is 10,000 cubic feet.

SPECIFICATIONS

  • INPUT POWER 120 V AC with 12V DC adaptor
  • POWER USAGE 4.0 watts at no alarm state; 6.0 watts at alarm state
  • ALARM INDICATORS Dry contact SPDT (5A, 250V) with red LED on enclosure, 85 dB internal buzzer
  • GAS DETECTED and Alarm Setting 20% LEL of Propane for Model HIC-813; 35ppm of Propane for Model HIC-822 (General Purpose)
Download Datasheet and Operation Instructions for Model HIC-813
Download Datasheet and Operation Instructions for Model HIC-822

FEATURES

  • 1-year limited warranty
  • Three methods of communicating alarm: 85dB internal buzzer, red LED and 10A, 250V dry relay
  • Equipped with a UL approved 120V AC to 12V DC, 500mA adaptor. 230V AC to 12V DC adaptor can be substituted if specified.
  • Programmable delay to activate the alarm relay. Delay are 0, 4 or 8 minutes. This reduces nuisance alarms caused by short whiffs of gas.
  • The recommended area for one detector is 10,000 cubic feet.

SPECIFICATIONS

  • INPUT POWER 120 V AC with 12V DC adaptor
  • POWER USAGE 4.0 watts at no alarm state; 6.0 watts at alarm state
  • ALARM INDICATORS Dry contact SPDT (5A, 250V) with red LED on enclosure, 85 dB internal buzzer
  • GAS DETECTED and Alarm Setting 20% LEL of Propane for Model HIC-813; 35ppm of Propane for Model HIC-822 (General Purpose)
Download Datasheet and Operation Instructions for Model HIC-813
Download Datasheet and Operation Instructions for Model HIC-822
  • Description

---

Description

Model HIC-813 or HIC-822 (General Purpose)

Propane Direct Hook Up

---

FEATURES

FEATURES

  • 1-year limited warranty
  • Three methods of communicating alarm: 85dB internal buzzer, red LED and 10A, 250V dry relay
  • Equipped with a UL approved 120V AC to 12V DC, 500mA adaptor. 230V AC to 12V DC adaptor can be substituted if specified.
  • Programmable delay to activate the alarm relay. Delay are 0, 4 or 8 minutes. This reduces nuisance alarms caused by short whiffs of gas.
  • The recommended area for one detector is 10,000 cubic feet.

---

SPECIFICATIONS

SPECIFICATIONS

  • INPUT POWER 120 V AC with 12V DC adaptor
  • POWER USAGE 4.0 watts at no alarm state; 6.0 watts at alarm state
  • ALARM INDICATORS Dry contact SPDT (5A, 250V) with red LED on enclosure, 85 dB internal buzzer
  • GAS DETECTED and Alarm Setting 20% LEL of Propane for Model HIC-813; 35ppm of Propane for Model HIC-822 (General Purpose)

Footer Start

Industrial Test Equipment Co., Inc.

Established in 1952, Industrial Test Equipment Co., Inc. (ITECO) produces AC power supplies and power amplifiers, hazardous gas detectors, wire markers, and engraved nameplates and tags for electrical and industrial applications.

location pin2 Manhasset Ave. Port Washington, NY 11050

phone 516-883-1700 | 516-883-7155

envelope sales@industrialtest.com

      • AC Voltage Sources 80-500 watts
      • AC Voltage Sources 1000-3000 watts
      • RF Power Amplifiers 50-1000 watts
      • AC Current Sources 250-500 watts
      • AC Current Sources 1000-3000 watts
      • Frequency Converters 80-3000 watts
      • AC Power Amplifiers (Voltage Mode)
      • AC Power Amplifiers (Current Mode)
      • Plasma Power Supplies
      • Dedicated AC Power Sources
      • IEEE Controlled Oscillators
      • Plug-in Oscillators
      • Three Phase Linear
      • Cable Markers
      • Engraved Nameplates and Tags
      • Hot Stamped Markers
      • Carbon Monoxide
      • Methane
      • Multi-Gas
      • Telecom
      • Propane
      • Hydrogen
  • Site Credits
  • Terms and Conditions
  • Privacy Policy
  • Warranty
  • Contact Us
  • © 2025 ITECO

© 2025 ITECO