Skip to main content
phone 516-883-1700
2 Manhasset Ave. Port Washington, NY 11050
Toggle menumenu toggle
Industrial Test Equipment Co., Inc.
  • Compare

  • Power Supplies expand drowpdown list close drowpdown list Power Supplies
    • AC Voltage Sources 80-500 watts
    • AC Voltage Sources 1000-3000 watts
    • RF Power Amplifiers 50-1000 watts
    • AC Current Sources 250-500 watts
    • AC Current Sources 1000-3000 watts
    • Frequency Converters 80-3000 watts
    • AC Power Amplifiers (Voltage Mode)
    • AC Power Amplifiers (Current Mode)
    • Plasma Power Supplies
    • Dedicated AC Power Sources
    • IEEE Controlled Oscillators
    • Plug-in Oscillators
    • Three Phase Linear
  • Labels & Markers expand drowpdown list close drowpdown list Labels & Markers
    • Cable Markers
    • Engraved Nameplates and Tags
    • Hot Stamped Markers
  • Gas Detectors expand drowpdown list close drowpdown list Gas Detectors
    • Carbon Monoxide
    • Methane
    • Multi-Gas
    • Telecom
    • Propane
    • Hydrogen
  • Sign in or Register
  1. Home
  2. Gas Detectors
  3. Multi Gas Direct Hook Up
Multi Gas Direct Hook Up
  • Multi Gas Direct Hook Up

Multi Gas Direct Hook Up

Model HIC-822 (General Purpose)

Multi Gas Direct Hook Up

MSRP:
Was:
Now: $320.00
(You save )
(No reviews yet) Write a Review

Write a Review

Multi Gas Direct Hook Up
Multi Gas Direct Hook Up

SKU:
HIC-822
UPC:
pdf:
HIC-822datasheet.pdf
model:
HIC-822
  • Facebook
  • Email
  • Print
  • Twitter
  • Pinterest
Multi Gas Direct Hook Up
  • Multi Gas Direct Hook Up

FEATURES

  • 1-year limited warranty
  • Three methods of communicating alarm: 85dB internal buzzer, red LED and 10A, 250V dry relay
  • Equipped with a UL approved 120V AC to 12V DC, 500mA adaptor. 230V AC to 12V DC adaptor can be substituted if specified.
  • Programmable delay to activate the alarm relay. Delay are 0, 4 or 8 minutes. This reduces nuisance alarms caused by short whiffs of gas.
  • The recommended area for one detector is 10,000 cubic feet.

SPECIFICATIONS

  • INPUT POWER 120 V AC with 12V DC adaptor
  • POWER USAGE 4.0 watts at no alarm state; 6.0 watts at alarm state
  • ALARM INDICATORS Dry contact SPDT (5A, 250V) with red LED on enclosure, 85 dB internal buzzer
  • GAS DETECTED AND ALARM SETTING 100ppm of Carbon Monoxide for model HIC-203; 20% LEL of Propane for model HIC-813; 20% LEL of Hydrogen for model HIC-821; 20% LEL of Methane for model HIC-842; 150ppm of Carbon Monoxide; 17ppm of Hydrogen 5000ppm of Methane; 35ppm of Propane for model HIC-822 (General Purpose)
Download Datasheet and Operation Instructions for Model HIC-822

FEATURES

  • 1-year limited warranty
  • Three methods of communicating alarm: 85dB internal buzzer, red LED and 10A, 250V dry relay
  • Equipped with a UL approved 120V AC to 12V DC, 500mA adaptor. 230V AC to 12V DC adaptor can be substituted if specified.
  • Programmable delay to activate the alarm relay. Delay are 0, 4 or 8 minutes. This reduces nuisance alarms caused by short whiffs of gas.
  • The recommended area for one detector is 10,000 cubic feet.

SPECIFICATIONS

  • INPUT POWER 120 V AC with 12V DC adaptor
  • POWER USAGE 4.0 watts at no alarm state; 6.0 watts at alarm state
  • ALARM INDICATORS Dry contact SPDT (5A, 250V) with red LED on enclosure, 85 dB internal buzzer
  • GAS DETECTED AND ALARM SETTING 100ppm of Carbon Monoxide for model HIC-203; 20% LEL of Propane for model HIC-813; 20% LEL of Hydrogen for model HIC-821; 20% LEL of Methane for model HIC-842; 150ppm of Carbon Monoxide; 17ppm of Hydrogen 5000ppm of Methane; 35ppm of Propane for model HIC-822 (General Purpose)
Download Datasheet and Operation Instructions for Model HIC-822
  • Description

---

Description

Model HIC-822 (General Purpose)

Multi Gas Direct Hook Up

---

FEATURES

FEATURES

  • 1-year limited warranty
  • Three methods of communicating alarm: 85dB internal buzzer, red LED and 10A, 250V dry relay
  • Equipped with a UL approved 120V AC to 12V DC, 500mA adaptor. 230V AC to 12V DC adaptor can be substituted if specified.
  • Programmable delay to activate the alarm relay. Delay are 0, 4 or 8 minutes. This reduces nuisance alarms caused by short whiffs of gas.
  • The recommended area for one detector is 10,000 cubic feet.

---

SPECIFICATIONS

SPECIFICATIONS

  • INPUT POWER 120 V AC with 12V DC adaptor
  • POWER USAGE 4.0 watts at no alarm state; 6.0 watts at alarm state
  • ALARM INDICATORS Dry contact SPDT (5A, 250V) with red LED on enclosure, 85 dB internal buzzer
  • GAS DETECTED AND ALARM SETTING 100ppm of Carbon Monoxide for model HIC-203; 20% LEL of Propane for model HIC-813; 20% LEL of Hydrogen for model HIC-821; 20% LEL of Methane for model HIC-842; 150ppm of Carbon Monoxide; 17ppm of Hydrogen 5000ppm of Methane; 35ppm of Propane for model HIC-822 (General Purpose)
  • Related Products
Hydrogen Direct Hook Up
Choose Options

Hydrogen Direct Hook Up

MSRP:
Was:
Now: $320.00 - $350.00
Propane Direct Hook Up
Choose Options

Propane Direct Hook Up

MSRP:
Was:
Now: $320.00
Methane Direct Hook Up
Choose Options

Methane Direct Hook Up

MSRP:
Was:
Now: $320.00
Carbon Monoxide Direct Hook Up
View Product The item has been added

Carbon Monoxide Direct Hook Up

MSRP:
Was:
Now: $150.00
Propane Back Up Generator
Choose Options

Propane Back Up Generator

MSRP:
Was:
Now: $185.00

Footer Start

Industrial Test Equipment Co., Inc.

Established in 1952, Industrial Test Equipment Co., Inc. (ITECO) produces AC power supplies and power amplifiers, hazardous gas detectors, wire markers, and engraved nameplates and tags for electrical and industrial applications.

location pin2 Manhasset Ave. Port Washington, NY 11050

phone 516-883-1700 | 516-883-7155

envelope sales@industrialtest.com

      • AC Voltage Sources 80-500 watts
      • AC Voltage Sources 1000-3000 watts
      • RF Power Amplifiers 50-1000 watts
      • AC Current Sources 250-500 watts
      • AC Current Sources 1000-3000 watts
      • Frequency Converters 80-3000 watts
      • AC Power Amplifiers (Voltage Mode)
      • AC Power Amplifiers (Current Mode)
      • Plasma Power Supplies
      • Dedicated AC Power Sources
      • IEEE Controlled Oscillators
      • Plug-in Oscillators
      • Three Phase Linear
      • Cable Markers
      • Engraved Nameplates and Tags
      • Hot Stamped Markers
      • Carbon Monoxide
      • Methane
      • Multi-Gas
      • Telecom
      • Propane
      • Hydrogen
  • Site Credits
  • Terms and Conditions
  • Privacy Policy
  • Warranty
  • Contact Us
  • © 2025 ITECO

© 2025 ITECO