Skip to main content
phone 516-883-1700
2 Manhasset Ave. Port Washington, NY 11050
Toggle menumenu toggle
Industrial Test Equipment Co., Inc.
  • Compare

  • Power Supplies expand drowpdown list close drowpdown list Power Supplies
    • AC Voltage Sources 80-500 watts
    • AC Voltage Sources 1000-3000 watts
    • RF Power Amplifiers 50-1000 watts
    • AC Current Sources 250-500 watts
    • AC Current Sources 1000-3000 watts
    • Frequency Converters 80-3000 watts
    • AC Power Amplifiers (Voltage Mode)
    • AC Power Amplifiers (Current Mode)
    • Plasma Power Supplies
    • Dedicated AC Power Sources
    • IEEE Controlled Oscillators
    • Plug-in Oscillators
    • Three Phase Linear
  • Labels & Markers expand drowpdown list close drowpdown list Labels & Markers
    • Cable Markers
    • Engraved Nameplates and Tags
    • Hot Stamped Markers
  • Gas Detectors expand drowpdown list close drowpdown list Gas Detectors
    • Carbon Monoxide
    • Methane
    • Multi-Gas
    • Telecom
    • Propane
    • Hydrogen
  • Sign in or Register
  1. Home
  2. Power Supplies
  3. AC Power Amplifiers (Voltage Mode)
AC Power Amplifiers (Voltage Mode)
  • AC Power Amplifiers (Voltage Mode)

AC Power Amplifiers (Voltage Mode)

For Use with  External 0-1V rms. Signal

MSRP:
Was:
Now:
(You save )
(No reviews yet) Write a Review

Write a Review

AC Power Amplifiers (Voltage Mode)
AC Power Amplifiers (Voltage Mode)

SKU:
148-80
UPC:

Adding to cart… The item has been added
  • Facebook
  • Email
  • Print
  • Twitter
  • Pinterest
AC Power Amplifiers (Voltage Mode)
  • AC Power Amplifiers (Voltage Mode)

FEATURES

Model
Output Power
Weight
80P
80 Watts
50 lbs
250P
250 Watts
70 lbs
350P
350 Watts
72 lbs
500P
500 Watts
75 lbs
1000P
1000 Watts
210 lbs
1500P
1500 Watts
225 lbs
2000P
2000 Watts
250 lbs
3000P
3000 Watts
260 lbs

SPECIFICATIONS

Output Circuit:
Isolated output transformer; taps from 0-8 to 0-260V for small units;taps from 0-65 to 0 - 3000V for big units
Regulation:
Adjustable to 0.1% line and load
Short Circuit Protection:
Automatic reset thermostat
Frequency Response:
Full power 45Hz-20KHz, reduced power 20Hz-40KHz
Distortion:
0.3% mid-band
Volt Meter:
Analog (not included in Model 80P)
Input Power:
115 or 230 volts 50 or 60 Hz for small unit, 208 3 phase 50/60 Hz for big units, unless otherwise specified can easily be wire for 190, 225, 240, 380, or 450V; 50/60 Hz.
Power Factor Range:
+0.7 to -0.7 for full power; to zero @ reduced power
Dimensions:
Standard 19” rack by 5.25” by 14” deep for small units
Standard 14” rack by 21” deep for 1000P and 1500P
Standard 17” rack by 21” deep for 2000P & 3000P

FEATURES

Model
Output Power
Weight
80P
80 Watts
50 lbs
250P
250 Watts
70 lbs
350P
350 Watts
72 lbs
500P
500 Watts
75 lbs
1000P
1000 Watts
210 lbs
1500P
1500 Watts
225 lbs
2000P
2000 Watts
250 lbs
3000P
3000 Watts
260 lbs

SPECIFICATIONS

Output Circuit:
Isolated output transformer; taps from 0-8 to 0-260V for small units;taps from 0-65 to 0 - 3000V for big units
Regulation:
Adjustable to 0.1% line and load
Short Circuit Protection:
Automatic reset thermostat
Frequency Response:
Full power 45Hz-20KHz, reduced power 20Hz-40KHz
Distortion:
0.3% mid-band
Volt Meter:
Analog (not included in Model 80P)
Input Power:
115 or 230 volts 50 or 60 Hz for small unit, 208 3 phase 50/60 Hz for big units, unless otherwise specified can easily be wire for 190, 225, 240, 380, or 450V; 50/60 Hz.
Power Factor Range:
+0.7 to -0.7 for full power; to zero @ reduced power
Dimensions:
Standard 19” rack by 5.25” by 14” deep for small units
Standard 14” rack by 21” deep for 1000P and 1500P
Standard 17” rack by 21” deep for 2000P & 3000P
  • Description

---

Description

For Use with  External 0-1V rms. Signal

---

FEATURES

FEATURES

Model
Output Power
Weight
80P
80 Watts
50 lbs
250P
250 Watts
70 lbs
350P
350 Watts
72 lbs
500P
500 Watts
75 lbs
1000P
1000 Watts
210 lbs
1500P
1500 Watts
225 lbs
2000P
2000 Watts
250 lbs
3000P
3000 Watts
260 lbs

---

SPECIFICATIONS

SPECIFICATIONS

Output Circuit:
Isolated output transformer; taps from 0-8 to 0-260V for small units;taps from 0-65 to 0 - 3000V for big units
Regulation:
Adjustable to 0.1% line and load
Short Circuit Protection:
Automatic reset thermostat
Frequency Response:
Full power 45Hz-20KHz, reduced power 20Hz-40KHz
Distortion:
0.3% mid-band
Volt Meter:
Analog (not included in Model 80P)
Input Power:
115 or 230 volts 50 or 60 Hz for small unit, 208 3 phase 50/60 Hz for big units, unless otherwise specified can easily be wire for 190, 225, 240, 380, or 450V; 50/60 Hz.
Power Factor Range:
+0.7 to -0.7 for full power; to zero @ reduced power
Dimensions:
Standard 19” rack by 5.25” by 14” deep for small units
Standard 14” rack by 21” deep for 1000P and 1500P
Standard 17” rack by 21” deep for 2000P & 3000P
  • Related Products
AC Power Amplifiers  (Current Mode)
Choose Options

AC Power Amplifiers (Current Mode)

MSRP:
Was:
Now:
RF Power Amplifiers 50-1000 watts
Choose Options

RF Power Amplifiers 50-1000 watts

MSRP:
Was:
Now:
AC Voltage Sources 80-500 watts
Choose Options

AC Voltage Sources 80-500 watts

MSRP:
Was:
Now:
AC Voltage Sources 1000-3000 watts
Choose Options

AC Voltage Sources 1000-3000 watts

MSRP:
Was:
Now:
Dedicated AC Power Sources
View Product The item has been added

Dedicated AC Power Sources

MSRP:
Was:
Now:

Footer Start

Industrial Test Equipment Co., Inc.

Established in 1952, Industrial Test Equipment Co., Inc. (ITECO) produces AC power supplies and power amplifiers, hazardous gas detectors, wire markers, and engraved nameplates and tags for electrical and industrial applications.

location pin2 Manhasset Ave. Port Washington, NY 11050

phone 516-883-1700 | 516-883-7155

envelope sales@industrialtest.com

      • AC Voltage Sources 80-500 watts
      • AC Voltage Sources 1000-3000 watts
      • RF Power Amplifiers 50-1000 watts
      • AC Current Sources 250-500 watts
      • AC Current Sources 1000-3000 watts
      • Frequency Converters 80-3000 watts
      • AC Power Amplifiers (Voltage Mode)
      • AC Power Amplifiers (Current Mode)
      • Plasma Power Supplies
      • Dedicated AC Power Sources
      • IEEE Controlled Oscillators
      • Plug-in Oscillators
      • Three Phase Linear
      • Cable Markers
      • Engraved Nameplates and Tags
      • Hot Stamped Markers
      • Carbon Monoxide
      • Methane
      • Multi-Gas
      • Telecom
      • Propane
      • Hydrogen
  • Site Credits
  • Terms and Conditions
  • Privacy Policy
  • Warranty
  • Contact Us
  • © 2025 ITECO

© 2025 ITECO